1600W Filter Modules Technical Information and Connection Details

Kemo 1600W filter modules are a modified version of the 1600 series filter modules, general specification, circuit layout, pin layouts and labelling are all the same.

   1600 Filter Module pdf data sheet (43 kB) file.


 The 1608 filter modules use 8 unlatched control lines to set the filter module cut-off frequencies, in multiples of the base frequency. 
HOWEVER only 100 of the frequency steps are used, The steps provide a psuedo-logarithmic set of frequency steps over a 1792:1 range.
A 20 Hz base frequency filter gives 100 filter steps in the range 20 Hz to 35 840 Hz. 

Setting the Frequency

The cut-off frequency of 1600W modules is set by 8 unlatched external logic lines. The control lines are active when low. In the recommended circuit the control lines are held high with 100 kΩ resistors and then switched low.
D0 is the least significant bit (LSB), D7 is the most significant bit (MSB) value 128 x base frequency. 
VDref is the supply voltage for the logic and control circuits in the module, and may be between +5V to +15V DC, the logic changes state at approximately 50% of VDref.
NOTE The filters can be damaged by code 11111111
REMEMBER Kemo logic control is ACTIVE LOW.


Frequency Codes
Fc Code
1 11111110
2 11111101
3 11111100
4 11111011
5 11111010
6 11111001
7 11111000
8 11110110
10 11110100
12 11110010
14 11110000
16 11101101
17 11101100
20 11101001
21 11101000
24 11100100
28 11100000
32 11011111
33 11011110
34 11011101
35 11011100
40 11010110
42 11010100
48 11001101
49 11001100
56 11000100
64 10111110
66 10111100
68 10111010
70 10111000
80 10101100
84 10101000
96 10011110
98 10011100
112 10001100
128 01111101
129 01111100
132 01111001
133 01111000
136 01110100
140 01110000
160 01011101
161 01011100
168 01010100
192 00111100
196 00111000
224 00011100
256 11011011
257 11011010
258 11011001
259 11011000
264 11010010
266 11010000
272 11001001
273 11001000
280 11000000
320 10011010
322 10011000
336 10001000
384 01011001
385 01011000
392 01010000
448 00011000
512 10110110
514 10110100
516 10110010
518 10110000
528 10100100
532 10100000
544 10010110
546 10010100
560 10000100
640 00110100
644 00110000
672 00010100
768 10010010
770 10010000
784 10000000
896 00010000
1024 01101101
1025 01101100
1028 01101001
1029 01101000
1032 01100100
1036 01100000
1056 01001101
1057 01001100
1064 01000100
1088 00101100
1092 00101000
1120 00001100
1280 01001001
1281 01001000
1288 01000000
1344 00001000
1536 00100100
1540 00100000
1568 00000100
1792 00000000


Any questions please contact us.

   1600 Filter Module pdf data sheet (43 kB) file.

Kemo Limited
3 Brook Court,
Blakeney Road,
Beckenham, Kent,
BR3 1HG.
United Kingdom

Tel:  +44 (0)20 8658 3838 
Fax: +44 (0)20 8658 4084
Kemo Inc.
5 Northbrook Way
Greenville,
SC 29615.
U.S.A.
 

Tel:  (864) 297 2522
Fax: (864) 675 1530