1200 series fixed frequency - 1600
series variable frequency
DR version - voltage output
DRI version 4-20mA output and voltage output
Filter frequencies from 0.1 Hz to >500 kHz
Signal frequencies from DC to >500kHz
Flexible inputs and gain
Adjustable Gain in 1,2,5 steps to x 1000 (+60dB)
4-20mA
current output DR
I
version
current source or current sink
Isolation (galvanic) between power and signal
circuits
Range of standard High pass / lowpass / notch filtering
9 Easy to use screw terminal connections
9 -30 V DC power input - ideal for 24V DC
Power on indication
2 Buffered voltage outputs
Optional +/- 50% output offset
28 mm ( 1.1") wide DIN rail case
Fits 35mm and 15mm DIN rails
255 step variable filter frequency (1600 series)
fixed filter frequency (1200 series)
Fast delivery
DIN Rail filter pdf data sheet (80 kB)
Order Now
Kemo DIN Rail filter
The Kemo DIN rail mounted filters units combine Kemo's
extensive
knowledge of signal filtering with a DIN rail case, screw connections, and a 24
V DC supply. With the combination of gain, easy installation, and a wide range
of filter responses the Kemo DIN Rail filters are an easy solution to many
industrial signal problems.
Filters are available to cover a wide range of applications, general purpose
noise reduction, anti-aliasing, signal reconstruction, and notch filters to
reduce unwanted frequencies, as well as traditional Butterworth and Bessel
filters.
Gain is set by easy access on board jumpers, with gain trim. Input
configurations are set by internal jumpers, the case opens without tools. Signal
and power connections are made by industry standard screw terminals.
See our Applications section
for a real problem solved using Kemo filters similar to the DIN Rail filters.
DIN Rail filters are available in two versions, DR for voltage outputs, and DRI
with voltage outputs and 4-20mA output.
Kemo have many years expertise in the field of small noisy signals,
contact us if you have any questions, or require further information.
For higher channel counts, >8 channels, all in one location, we suggest you take
a look at the CardMaster 21.2 page.
Summary Specification
Channels
1 per unit
Control
Manual - jumpers and DIP switches
DR and DRI1200 - Fixed frequency.
DR and DRI1600 - 255 steps set by DIP switch
Connectors
DR version 9 Screw terminals (3 x blocks of 3)
DRI
version 12 Screw terminals (4 x blocks of 3)
Frequency
1200 series 0.1 Hz - >500 kHz
1600 series 255 steps x 'Base' frequencies of 1,2,5,10,20,50,100,200,500
Hz
Gain
x1,x2,x5,x10,x20,x50,x100,x200,x500,x1000 set by jumpers
Filters
1200 series - 1200 series
filter modules
1600 series - 1600 series filter modules
Filter Responses
01
Anti-aliasing, sharp >135 dB/Oct, flat to cut
off, high and lowpass 03,
48 dB/Oct Butterworth, high and lowpass 05,
24 dB/Oct Butterworth, high and lowpass 07,
48 dB/Oct Bessel, high and lowpass 09,
24 dB/Oct Bessel, high and lowpass 41,
General Purpose, flat to cut off, linear
phase, 52 dB/Oct, high and lowpass NQ10 Sharp Notch
Input Coupling
AC / DC ( Matched AC coupling
on Differential Input)
AC coupling
-3dB at 1.5 Hz
Input Mode
Single Ended / Differential
Voltage
Input Impedance
1MΩ
Current Input Impedance
500 Ω (4-20mA input)
IEPE
4mA 24V current source
(can be set to higher current on request)
Signal Level
+/- 10 V pk-pk. (Usually with 'headroom')
Offset
Multi-turn trim,
Optional +/- 50% adjustment (specify 'O' at order)
Outputs
DR version 2 Voltage
DRI
version 2 voltage and 4-20mA 'source' and 'sink'
4-20mA Bandwidth
10 kHz
Output Impedance
47 Ω
Power Indicator
LED power on indicator
Size
27 x 83 x 114 mm (1.1 x 3.3 x 4.5")
mounts on standard 35 and 15 mm DIN rails
Power
9 - 30 V DC 2 watt typical (ideal for +24 V DC)
Inputs
Both versions of DIN Rail filters have the same flexible configurable input stage. Single Ended / Differential - The units are fundamentally
differential input. Single ended input is easily set by either an internal
jumper or an external link to zero volts on the input screw terminals. Note
all the connector blocks have a zero volt terminal. AC / DC Coupling - is set by internal
jumpers. The AC coupling is matched to both legs of the differential inputs. IEPE - a 4mA current source is provided for use with IEPE
transducers, this is set by an internal jumper. Higher currents can be set
up to 10mA. 4-20 mA Input -
this input is a 500 Ω
resistor across the differential inputs, the incoming 4-20mA signal is
converted to a
2-10V voltage signal. This input can be set to differential input to give a
semi-floating input, or set to single ended to tie the
input to signal zero volts.
Input Gain
The input gain is set by jumpers:-
x1,x2,x5,x10,x20,x50,x100,x200,x500,x1000.
There is a small gain trim of about +/- 10%, depending on filter type
fitted.
Filters
The standard range of Kemo lowpass and highpass filter modules can be fitted
to the DIN Rail filters. A sharp notch filter, response NQ10, is available for
50Hz or 60Hz applications.
1200 series DIN rail units are fixed frequency.
1600 series DIN rail units have variable frequency filter modules, 255
filter steps set by an easy to use DIP switch.
Voltage Outputs
Both versions of DIN Rail rail filters have 2 identical buffered voltage outputs.
DRI version with 4-20mA Outputs
The DRI version adds a 4-20mA output.
The filtered voltage
is reconverted to a 4-20mA current signal. The output current can be configured
EITHER as a current source using the isolated +24V power supply built in the
unit, OR as a current sink, where an external +24 supply can be used. This
provides a very versatile flexible system.
Order as DRI version.
Optional Output Offset
Optional output offset after the filter, before the output buffers,
adjustable by multi-turn pot over a +/- 50% of output full scale.
Order as option 'O'.
DC Power
-
The 9-30V DC power input in this unit uses conversion methods, please check our
page about DC Power.
System Diagrams
DR Version - 2 Voltage Outputs
DRI Version - 4-20mA Output and 2 Voltage Outputs
Ordering Information
Specify version DR voltage version OR DRI with additional
4-20mA current output
Specify 1200 series fixed
frequency OR 1600 series variable frequency
Specify cut off frequency 1200 Series
Specify frequency range 1600 Series ('base frequency' to 255 x 'base
frequency')
Specify filter type, highpass, lowpass or notch.
Add 'O' for +/- 50% Optional output offset.
If you need any help please contact us.
DIN Rail filter pdf data sheet (80 kB)
Order Now
●
Kemo Limited
Unit 1, Dene Yard,
Green Street Green Road
Dartford, Kent,
DA2 8DH.