- Compact 16 and 8 channel systems
- Programmable Gain and Frequency
- RS232 ASCII Text based Computer control
- Windows™ Driver
- Range of filter responses and frequencies
- Programmable Gain to +58dB (x800)
- Designed for portable use
- DC Power input
- Optional IEPE transducer supply
- Systems from 0.2 Hz - 127 500 Hz
RackMaster pdf format data sheet
(73 KB)
|
|
The Kemo RackMaster Series of filter systems, are compact
filter amplifiers, in a range of rugged cases suitable for portable or
laboratory filter/amplification tasks. The programmable systems are controlled by an
RS232 text based interface, using the Kemo FICL
control language. Windows drivers are available. RackMaster systems have
controllable inputs, AC / DC coupling and filter bypass set by computer, and
single ended / differential / IEPE inputs set by front panel switches.
Input gain is computer controlled between -6 dB (x0.25) to +58 dB (x800), to
reduce noise unused channels can be grounded. Filter frequencies are
available from 0.2 Hz, and are usually based on the Kemo 1600
filter modules.
RackMasters can be made in fixed or manually set versions, a number of these
have been made for applications where the filter is 'hard set' in the
laboratory and then taken on site pre-set with no further programming
requirement.
Summary Specification
| Channels |
1 - 16 |
| Control |
RS 232 FICL,
Kemo Windows driver |
| Frequency |
0.2 Hz - 255 kHz |
| Gain |
-12 to +58 dB |
| Filters |
1600
or 1600W filter
modules |
| Filter Responses |
Defined by filter
modules |
| Input Coupling |
AC / DC / IEPE |
| IEPE |
Yes 4mA 20V |
| Size |
1U 19" |
| Power |
9 - 30 V DC, with AC 'power brick'
See notes on DC power |
Programmable Frequency and Gain
The RackMster uses Kemo's 1600 Series Filter
Modules, offering exceptional analogue performance in a small volume. Each
1600 filter module can be programmed over a 255:1 range,1792:1 for the 1600W
filter modules. Cut-off frequencies from 0.2 Hz to 255 kHz are available as
standard, with others available to special order. Please contact us with
your requirements.
The filter modules plug into the RackMaster, so should you wish to change
filter response or frequency in the future this is possible
The RackMaster has 3 programmable gain ranges,
| Gain Range |
Gain Steps |
| 0.25 - 7.75 (-12 to 17.7dB) |
32 steps of x0.25 |
| 5 - 80 (14 to 38 dB) |
16 steps of x 5 |
| 50 - 800 (34 to 58 dB) |
16 steps of x 50 |
Control
RackMasters are controlled by RS232
interface, using the Kemo FICL text based control language, or a
supplied Windows driver.
FICL is a text based command set, very easy
to understand and program, the filter settings can be controlled by
any device with an RS232 interface. Some of our customers use PDA's
to control their filters.
Programming is also very easy using the FICL commands. e.g.:
FREQ 1,500
Sets filter channel 1 to 500 Hz.
The Kemo Windows driver for the RackMasters has features to aid the traceability of the measurement
settings.
Once a set of commands are set to the RackMaster, the driver then interrogates
each channel of the RackMaster, and saves the results as a text file. This gives
a record of the actual filter settings, these files can be stored and used
as part of a measurement control system.
A typical screen is shown to the left.
A table is created and then sent to the RackMaster, channels 2 and 3 have data
to send, channels 5 and 6 have been sent data, which the driver corrected to
suit the available filter settings, all other channels are set. |
|
Racks
| Two rack sizes are available, 19"
1U, and
the compact 8 channel version shown here. |
|
RackMaster pdf format data sheet (73 KB)
|